Ministries District New Capital

Project Overview

Case

  • Water leakage in all basements in this district Due to presence of landscape & presence of defects in the old waterproofing system.

Problem

  • Water leakage in Joints, Kickers & Walls.

Solution

  • Technnoinjection 304 Acrylic Gel was applied to the Joints, Kickers & Walls.
  • Technoinjection 304 has a setting time of 10 secs, elongation up to 750%, strong Adhesion to concrete.